Minimum pressure:
*Material, ...
*Min pressure
<minimum pressure>
This parameter is used to correct small effective pressures in case barotropic constitutive models are used. Set this pressure to the minimum allowed pressure (mechanical sign convention, i.e. give a negative value). This parameter should be set for the following materials:
Model | Section |
---|---|
Hypoplasticity + Intergranular Strain | 5.5.2.3 |
Hypoplasticity + Intergranular Strain Anisotropy | 5.5.2.6 |
Sanisand | 5.5.2.7 |
Modified Cam Clay | 5.5.2.10 |
Anisotropic Viscous ISA | 5.5.2.12 |
High Cycle Accumulation model for sand | 5.5.2.9 |
... coupled with Hypoplasticity + Intergranular Strain | |
... coupled with Sanisand | |
High Cycle Accumulation model for clay | 5.5.2.16 |